KAIR ECoRotor 5280 with rotating heat recovery
KAIR ECoRotor 5280 with rotating heat recovery
Properties
- fully assembled, ready-to-use system
- easy to transfer to the site, can be dismantled into sections
- rotary heat recovery system
- supply and exhaust air volume: 0.3–1.2 m³/s
- dimensions 2376 x 1250 x 1730 (LxSxK)
- duct connections 4 x Ø 500 mm on the top and/or on the side
- energy efficient, EC fans
- re-heating with water or electricity
- equipped with its own control system or automation substation connectivity
- requires little space, compact in relation to its capacity
Internal cooling system
- a water cooling coil or
- a direct evaporation coil
Installation
- can be dismantled into sections, electricity and automation between sections can be connected with quick couplers
- fits through an 1000-mm wide door
- comes fully assembled, easy and quick to install
- automation, testing and electric connections are performed before delivery
- only connections to the power supply, duct system and the drain for condensed water are carried out on-site (external cabling for models with automation substation connectivity)
Applications
With KAIR ECoRotor 5280 you get affordable, reliable and highly energy-efficient ventilation. Vertical/horizontal unit is easy to fit even in small spaces.
-
- Offices
- Small industrial facilities
- Day care centers
- Schools
- Restaurants
KAIR ECoCounter 1185 with counter-flow coil
Properties
- fully assembled, ready-to-use air handling unit with a counter-flow heat exchanger
- supply and exhaust air volume: 0.08 – 0.3 m³/s
- dimensions: 1350 x 780 x 1650 mm (WxDxH)
- duct connections: 4 x Ø 250 mm, on the top
- energy efficient, EC fans
- re-heating with water or electricity
- equipped with a Fidelix FxVent, Ouman Ouflex A or Siemens Climatix control system or automation substation connectivity
- requires little space, compact in relation to its capacity
Internal cooling system
- water cooling coil (-JP4)
- direct evaporation coil (-HP)
Installation
- fits through an 900 mm wide door
- comes fully assembled, easy and quick to install
- automation, testing and electric connections are performed before delivery
- only connections to the power supply, duct system and the drain for condensed water are carried out on-site (external cabling for models with automation substation connectivity)
Technical documentation for the system can be found in the selection program
Contact
Sales

Markus Luokkanen
Northern sales region

Matias Luokkanen
Helsinki, Espoo, and Vantaa

Janne Mikkola
Eastern sales region
Jarkko Pulli
Product Manager (design support)

Tomi Lähde
Western sales region

Jaana Holma
Sales Assistant
Spare parts and technical consultancy
Technical consultancy, under warranty

Jouni Kousa
electical and automation
Administration

Tatu Hartikainen
Managing Director

Pasi Paaso
Technical Director

Kim Gustafsson
Operation Manager
Warranty
Production and dispatch

Lauri Asiala
Production Manager
Finance

KAIR ECoCounter 6585 with counter-flow coil
Properties
- fully assembled, ready-to-use system
- easy to transfer to the site, can be dismantled into sections
- equipped with a counter-flow heat exchanger
- supply and exhaust air volume: 0.5–1.6 m³/s
- dimensions: 2800 x 1800 x 2080 mm (WxDxH)
- duct connections 4 x Ø 630 mm, on the top and/or on the side
- energy efficient, EC fans
- re-heating with water or electricity
- equipped with a Fidelix or Outflex control system or automation substation connectivity
- requires little space, compact in relation to its capacity
Internal cooling system
- integrated compressor cooling system (-ICC), with a capacity of 16, 22, 29 kW
- water cooling coil (-JP4 or -JP6)
- direct evaporation coil (-HP)
Installation
- can be dismantled into sections, electricity and automation between sections can be connected with quick couplers
- fits through an opening of 1000 x 1830 mm (as components), 1830 x 2090 mm (assembled)
- comes fully assembled, easy and quick to install
- automation, testing and electric connections are performed before delivery
- only connections to the power supply, duct system and the drain for condensed water are carried out on-site (external cabling for models with automation substation connectivity)
Technical documentation for the system can be found in the selection program
KAIR ECoCounter counter-flow systems
Applications:
Day care centres, schools, offices, assisted living facilities, centralised air conditioning for blocks of flats, restaurants, business premises, offices, industrial facilities, and workplace staff facilities.
Ecodesign Directive ErP2016 and ErP2018 (2009/125/EC).
KAIR ECoCounter systems are designed to meet the criteria set forth in the new European Ecodesign Directive.The changes brought about by the new directive primarily pertain to the requirements for the efficiency of heat recovery and SFP calculation.The directive stipulates that as of 1 January 2016, the minimum thermal efficiency of heat recovery systems is 67%, and 73% from 1 January 2018 onwards.The ECoCounter products’ thermal efficiency of heat recovery is 79–88% (depending on air quantities, with proportions of 1:1).With changes such as an increased filter area, the system is designed to minimise internal loss of pressure.The new models will replace the old systems that utilised cross-flow heat recovery technology.
Compact in size
The air conditioner offers flexibility in installation, with duct connections available on the top, on the sides or on both 1).The system is easy to transport.The ECoCounter 1085 and 2185 devices can fit through an 800-mm wide opening, while the larger models require a 900-mm opening.
1)The ECoRotor 1085 has duct connections on the top
Cooling
The system is available with three cooling options 2).The size of the device remains the same, irrespective of the cooling solution.
-The compressor cooling solution (-CO) (available in a range of efficiency classes) comes with all the cooling components installed and tested.
-The water cooling coil system (-JP) is available with two coil types.The JP4 is suitable for water temperatures of 7–12°C, while the JP6 (district cooling solutions) is designed for water temperatures of 10–15, 10–16 and 10–18°C.
-Used with separate external units, evaporation coils (-HP) are also suitable for heat pump solutions.
2) The ECoCounter 1085 is only available with the coil (-JP4), suited for water temperatures of 7–12°C
Electricity and automation
A system that is tested and automated before delivery is the easiest and most cost-efficient solution.The device comes complete with an electricity and automation unit.The system is available with three automation levels.
-Fidelix Multi 24+ screen (FIM).Installed and tested before delivery.Three-speed control (normal, maximum and night modes).Can be connected to other automation systems via the Modbus RTU. 3)
-Automation substation connectivity.Actuators come connected to a connection strip.The actuators are included in the delivery.
-Ouman Ouflex.Installed and tested before delivery.Three-speed control (normal, maximum and night modes).Can be connected to other automation systems via the Modbus TCP/IP.
3) The ECoCounter 1085 is not available with the Fidelix system.
Antifreeze solutions for the heat recovery unit
The systems are available with two frost control solutions: a bypass defrosting system (KAIR Frost Control) and a sequential defrosting system.The sequential defrosting system contributes to a higher coefficient of performance, thereby decreasing the need for post-heating power.